Hercules Boiler Model 19
Trouble-Shooting
1. Smoke comes out of the stove when the loading door is opened.
The chimney cavity into which the flue pipe has been installed may be less
than the minimum requirement.
Deposits (soot) may have built up in the chimney and be restricting the flow
of waste products. This flow rate is known as the ‘draw’.
2. The Stove does not produce the expected heat into the room.
Has the flue pipe been sealed to the chimney to prevent heat being drawn up
the chimney to waste?
Green or wet wood is being burnt.
There is insufficient draw in the chimney. Seek installer advice with regards to
fitting a cowl.
The chimney has excessive draw (this is unusual). Seek installer advice with
regard to installing a Flue Draught Stabiliser.
The stove has been recessed into the existing fireplace and a lot of heat is
absorbed be the surrounding fireplace walls rather than being radiated into
the room. Pull the stove forward.
For the maximum efficiency of heat transference into the room the stove
should be sited on the hearth of the fireplace rather than recessed.
There is insufficient air supply into the room.
An extractor fan has been fitted in the same room.
3. The Stove burns too fast.
Use whole logs rather than split ones.
The wood being used may be generally too small.
The “air-tight” seal between the fibre rope on the doors and the casting may
have been lost, adjust door handle lock nuts/washers to reinstate this seal.
The chimney has excessive draw (seek installers advice on this point).
The fibre rope seal between the door and the glass may be leaking. Tighten
or replace.
The glass is not sealed, gently tighten glass retaining clips. Do not over
tighten as this will stress or break the glass.
4. Over Firing
If the appliance is over fired it will cause premature failure to the internal
parts of the appliance. Over firing occurs when excessive heat is generated
by the fuel being burnt due to a lack of control of the fire.
Insure the door seals are kept in good condition and that the doors are
sealing correctly.
Insure the thermostat control and other air controls are functioning correctly
The correct fuel for the appliance is being used i.e. you are burning fuel
suitable for a closed appliance.
5. Lack of Heat to Radiators/Hot Water
a) The fire is burning properly – if not then carry out the checks on the ‘The
Stove does not produce the expected heat into the room’
b) The baffle plate is fitted correctly
c) The door seals are in good condition
d) If there is a lack of hot water or the water goes cold when the pump is
turned on, or if some radiators are hotter than others the system may need
to be balanced. The pump may be pumping water around your system to
quickly or some or all of the radiators may need bleeding. Your installer can
check on these points.